📞 (703) 437-8161

✉ info@capitalenergyequipment.com

DISIO

DISIO by Price Industries
by Price Industries
BACnet MS/TP 4 UI / 4 UO Patented Cloud BMS BTL Listed

Intelligent Building Controls
Built for Comfort

The DISIO ecosystem delivers precision zone-level control — from a single smart thermostat to a complete cloud-connected building management system supporting up to 24,000 points.

Explore Control Sequences ↓
4 UI / 4 UO
Universal I/O
24,000
Max BACnet Points
BACnet
MS/TP Protocol
Patented
Gesture Presence
DISIO Display Thermostat
Product

DISIO Display Thermostat

A versatile zone controller engineered for fan coil, pressure-dependent terminal, reheat, hydronic, and standalone heater applications. Connects over BACnet MS/TP or operates fully standalone.

4 UI
Universal Inputs
4 UO
Universal Outputs
7-Seg
Display
USB-C
Setup Port
Capacitive Touch Gesture Presence Sensing 24VAC Power BACnet MS/TP Switched HOT/COM Jumper RoHS Compliant
Patented
Control Diagrams

Control Sequence Explorer

DISIO supports a broad library of BACnet-configurable sequences for any HVAC application. Select a category to explore.

2-Pipe Binary HCCO
Fan Coil · 2-Pipe
DX-300

Single binary valve with heat/cool changeover sensor. Controller opens or closes the valve based on room demand; water-side HCCO sensor prevents valve actuation against wrong-mode supply.

Room Temp Valve SP ON OFF Temp Valve
1 Binary Valve HCCO Sensor Fan Speeds
2-Pipe Modulating HCCO
Fan Coil · 2-Pipe
DX-301

0-10VDC modulating single valve with HCCO. Valve position tracks proportionally to room demand. HCCO sensor prevents opening against wrong-temperature supply water.

Valve % Demand SP 0-10V Temp Valve
0-10VDC Valve HCCO Sensor ECM Fan
4-Pipe Binary Valves
Fan Coil · 4-Pipe
DX-302

Separate binary cooling and binary heating valves. Controller selects cooling or heating based on room demand with a dead-band between modes. No changeover sensor required.

Valve State SP HEAT COOL
Binary Cool Valve Binary Heat Valve 3-Speed Fan
4-Pipe Mod Cool / Binary Heat
Fan Coil · 4-Pipe
DX-303

Modulating 0-10VDC cooling valve for precise capacity control; binary 24VAC heating valve for on/off heat. Optimal for systems with variable chilled water but constant hot water.

SP 0-10V Cool Bin Heat
0-10VDC Cool Binary Heat ECM Fan
4-Pipe Modulating Cool & Heat
Fan Coil · 4-Pipe
DX-304

Independent 0-10VDC modulating valves for both cooling and heating. Maximum comfort precision — each valve position responds proportionally to its respective demand.

SP Cool Heat
0-10VDC Cool 0-10VDC Heat ECM Fan
4-Pipe Binary Cool / Mod Heat
Fan Coil · 4-Pipe
DX-305

Binary 24VAC cooling valve with modulating 0-10VDC heating valve. Suited for systems needing high-resolution heating control (e.g., radiant supplemental or electric coil) with simple on/off chilled water.

SP Bin Cool Mod Heat
Binary Cool 0-10VDC Heat 3-Speed Fan
Reheat Application
Reheat · Multi-Output
DX-50

On demand for heat, the controller energizes any output configured for heating. Supports 0-10VDC modulating, 2-10VDC, 24VAC binary, or tri-state outputs. Up to 2 stages of binary heat configurable via Setup software.

Heat Output SP 0-10V Bin Stg1
0-10VDC Heat Binary Stg 1 & 2 2-10VDC Tri-State
Linear Gate Bypass + HCCO
Pressure Dep. · Bypass
DX-100

Pressure-dependent damper sequence with linear gate bypass and heat/cool changeover. Tri-state or 0-10VDC actuator positions the damper. HCCO sensor governs heating/cooling selection from duct supply.

Damper % SP Damper Min
Tri-State Damper HCCO Sensor SAT Probe
Pressure Dependent + HCCO
Pressure Dep. · Terminal
DX-101

Pressure-dependent VAV damper control with HCCO. Damper position modulates from minimum to maximum based on zone demand. Changeover from duct supply temperature sensor determines mode.

SP Cool Heat Min
0-10VDC Damper HCCO BACnet Override
PI Damper + HCCO + Opt. Reheat
Pressure Independent · Airflow Module Required
DX-150

True pressure-independent control using the Disio Airflow Module (0.25–4 VDC differential pressure signal) to maintain precise CFM setpoints. If Airflow Module is not detected, controller automatically falls back to pressure-dependent control. Optional 24VAC binary reheat and/or 0-10VDC modulating reheat. SAT sensor required for HCCO.

Cool Air → Warm Air → SP Max Cool CFM Reheat ON Min CFM
Airflow Module (req.) HCCO / SAT Sensor Binary Reheat (opt.) 0-10V Reheat (opt.) Tri-State Actuator
🌀
Airflow Kit Required

DX-150 requires the Disio Airflow Module for true pressure-independent control. Without it, the controller automatically reverts to position-based (pressure-dependent) operation.

0.25–4 VDC · 0–2″ W.C.
2-Pipe Binary HCCO
Chilled Beam · Hydronic
DX-500

Binary valve for radiant/chilled beam 2-pipe system. HCCO supply temperature sensor prevents valve opening against wrong-mode water. Optional condensate sensor closes valve on detection. Auto-purge: valve opens for 5 min after 10 hrs closed to check water temperature.

SP ON OFF Temp Valve
Binary Valve HCCO Sensor Condensate Sensor
2-Pipe Modulating HCCO
Chilled Beam · Hydronic
DX-501

0-10VDC modulating single valve for 2-pipe chilled beams. Valve position tracks proportionally to demand — cooling or heating depending on HCCO sensor reading. Condensate sensor closes valve; auto-purge checks supply temp after 10-hr closure.

SP 0-10V Room Valve
0-10VDC Valve HCCO Sensor Condensate Sensor
4-Pipe Binary Valves
Chilled Beam · Hydronic
DX-502

Separate binary cooling and heating valves for 4-pipe chilled beams. Controller energizes the appropriate valve per demand with a dead-band preventing simultaneous operation. Condensate protection included.

SP Cool Heat
Binary Cool Valve Binary Heat Valve Condensate Sensor
4-Pipe Modulating Cool & Heat
Chilled Beam · Hydronic
DX-503

Premium 4-pipe chilled beam with independent 0-10VDC cooling and heating valve modulation. Highest level of comfort control for radiant systems. Dead-band prevents simultaneous heating and cooling. Condensate sensor protection.

SP Cool 0-10V Heat 0-10V
0-10VDC Cool 0-10VDC Heat Condensate Sensor
PRODIGY® Smart Diffuser
VAV Diffuser · Up to 5 Drones
DX-600

Controls the PRODIGY® Smart Diffuser system. One DISIO Display acts as master controller for up to 5 drone diffusers connected via RJ-50 daisy-chain. Each drone adjusts airflow independently based on zone demand. Ideal for open-plan and multi-zone VAV ceiling applications.

DISIO D1 D2 D3 Airflow Min Drone airflow (each) RJ-50 daisy-chain · max 5 drones
Up to 5 Drones RJ-50 Daisy-Chain BACnet MS/TP PRODIGY® Compatible
💨
Smart Zone Distribution

The PRODIGY® Smart Diffuser with DX-600 enables individual airflow control at each diffuser — eliminating traditional VAV boxes while maintaining BACnet integration and zone-by-zone comfort management.

Typical EF Panel
Special · Exhaust Fan
EF Panel

DISIO configured for typical exhaust fan panel control. Outputs manage fan stages, occupancy-based switching, and status reporting over BACnet MS/TP.

Fan Stages Occupancy BACnet Status
Remote Sensor Application
Special · Sensor
Remote

DISIO operates as a remote sensor node — reporting temperature, CO₂, and/or RH over BACnet MS/TP to a host BMS without local control outputs.

Remote Temp CO₂ Monitoring RH Sensing
Fire Station EF
Special · Emergency
Fire EF

Emergency exhaust fan sequencing for fire station or life-safety applications. Outputs respond to fire alarm inputs and BACnet commands with defined fail-safe behavior.

Fire Alarm Input Fail-Safe BACnet Override
MUA Control
Special · Make-Up Air
MUA

Make-up air unit control using DISIO Display. Manages heating/cooling outputs for the MUA unit with occupancy scheduling and BACnet integration for central BMS override.

Heating Stage Cooling Stage Occupancy Sched.
Humidifier Status
Special · Humidity
RH

DISIO monitors and reports humidifier status via BACnet. Configurable relative humidity setpoints with alarm outputs. Compatible with monitoring-only and active control configurations.

RH Sensor Humidifier Output BACnet Alarm
DISIO Cloud BMS
Product

DISIO Cloud BMS

A complete cloud-based building management solution. The Hub pulls BACnet points from all DISIO controllers and retains data in the cloud — accessible from any device, anywhere in the world.

🔐
Two-Step AuthenticationSecure access for building operators and engineers
📱
Any Device, AnywhereAvailable on iOS (App Store) and Android (Google Play)
🗂️
Pre-Built GraphicsReady-made dashboards for all Price Controls products
📦
Optional Pre-Wired PanelAll Cloud equipment factory-mounted and pre-wired
Subscription Packages
3,000 Points 6,000 Points 12,000 Points 24,000 Points
Add-On Module

DISIO Airflow Kit

Enables precise airflow monitoring and control when paired with the DISIO Display. The module converts differential pressure from a crossflow sensor to a 0.25–4 VDC signal, enabling full pressure-independent terminal control (DX-150).

Output Signal0.25–4 VDC (proportional to 0–2″ W.C.)
Power24VAC terminal block
CalibrationField-calibrated via DISIO Setup Software
StatusDiagnostic LED on module
Fail-SafeAuto-reverts to pressure-dependent if disconnected
DISIO Airflow Module
Software

DISIO Setup Software

Free Windows configuration tool for commissioning and programming every DISIO Display. Connects via USB-C — no network required.

  • Configure all 4 universal inputs and outputs (type, function, range)
  • Set control sequence parameters, setpoints, and proportional bands
  • Calibrate the Airflow Module’s zero offset (DX-150)
  • View live BACnet point values and override in field
  • Configure BACnet MS/TP address, baud rate, and polling settings
  • Download free at disio.io/setup
Download Setup Software →
DISIO Setup Software on laptop
Get Started

Specify DISIO on Your Next Project

Capital Energy Equipment is your local source for DISIO by Price Industries. Our team can assist with sequence selection, submittals, and application support.