📞 (703) 437-8161

✉ info@capitalenergyequipment.com

Arrow United Industries

← Manufacturers/Arrow United Industries
Louvers & Dampers

Arrow United Industries

Fire, smoke, and combination dampers — UL-listed and built to code for life-safety compliance in commercial, healthcare, and high-rise construction.

Fire DampersSmoke DampersCombination DampersCeiling Radiation DampersUL ListedIBC/IMC Compliant
Visit Arrow United Industries Website →
UL Listed
All Products
IBC/IMC
Code Compliant
1.5 & 3 Hr
Fire Ratings
Full Line
Damper Types

Solutions & Product Series

Arrow United Industries manufactures a complete line of UL-listed fire, smoke, and combination dampers for commercial and institutional HVAC systems. All products comply with NFPA 90A/90B, IBC, IMC, and UL 555/555S standards — providing the life-safety performance and documentation required on every project.

Fire Dampers
UL 555 listed fire dampers for rated wall and floor assemblies
UL 555
  • Dynamic and static fire dampers — UL 555 listed
  • 1.5-hour and 3-hour fire resistance ratings
  • Curtain blade and multi-blade designs
  • Fusible link: 165°F standard, 212°F and 286°F available
  • Sizes from 4×4″ to 48×48″ in standard configurations
  • Sleeve lengths to match wall/floor assembly depth
Smoke Dampers
UL 555S listed smoke dampers for smoke control systems
UL 555S
  • UL 555S listed — Class I and Class II leakage ratings
  • Electric fail-safe actuators — spring return to closed
  • Operating range: -40°F to 250°F
  • BACnet, Modbus, or end-switch position feedback
  • Actuator brands: Belimo, Honeywell, Siemens
  • Required by code in smoke control and pressurization systems
Combination Fire/Smoke Dampers
Single unit meets both fire and smoke damper requirements
Combination
  • Dual-rated: UL 555 + UL 555S in one assembly
  • 1.5-hour and 3-hour fire resistance ratings
  • Class I or Class II leakage
  • Spring-return actuator with thermal element backup
  • Eliminates need for separate fire and smoke dampers
  • Preferred by AHJs for simplified installation
Ceiling Radiation Dampers
Fire-rated dampers for ceiling membrane penetrations
UL 555C
  • UL 555C listed ceiling radiation dampers
  • Round and rectangular configurations
  • Fusible link closure: 165°F standard
  • Fits lay-in T-bar and gypsum ceiling assemblies
  • Listed for use without sleeve in T-bar ceiling applications
  • Sizes: 6″ to 24″ round, standard rectangular sizes

Key Advantages

🔥
Life-Safety Compliance
Every Arrow United damper is UL listed and complies with NFPA 90A/90B, IBC, and IMC — providing documentation and labeling required by inspectors and AHJs.
📋
Complete Documentation
UL listing cards, installation instructions, and submittal data sheets provided for every order — simplifying review and approval.
⚙️
Actuator Flexibility
Smoke and combination dampers available with Belimo, Honeywell, or Siemens actuators — matching the preference of your controls contractor.
🔧
Field-Verified Ratings
Arrow United products are independently tested and listed — not self-certified — providing confidence under inspection.
📐
Wide Size Range
Standard dampers from 4×4″ to 48×48″ with custom sizes available for oversized penetrations.
🏥
Healthcare Expertise
Extensive experience in healthcare and high-rise projects where smoke control requirements are most demanding.
Applications & Markets Served
Healthcare & HospitalsHigh-Rise Office TowersHotels & ResortsSchools & UniversitiesData CentersGovernment BuildingsCorrectional FacilitiesPerforming Arts CentersUnderground ParkingAtriums & StairwellsSmoke Control SystemsNFPA 92 Pressurization

Specify Arrow United Industries on Your Next Project

Contact Capital Energy Equipment for product selection, submittals, and engineering support.