πŸ“ž (703) 437-8161

βœ‰ info@capitalenergyequipment.com

NJK Precision

← Manufacturers/NJK Precision
Precision Airflow Measurement β€” Patented Technology

NJK
Precision

Patented dual-chambered airfoil airflow measuring stations and damper louver solutions β€” inspired by aviation and automotive technology to deliver NIST-certified accuracy down to 50 FPM in any HVAC application.

πŸ“ Airflow Measuring StationsπŸ”© Damper Louver SolutionsπŸ”¬ NIST-Certified Accuracy🏭 Multi-Sensor Hub
21
Patented Claims
Β±0.19%
Calibration Uncertainty
50 FPM
Minimum Flow Detected
8 Sensors
Per SPU-M Hub

Airflow Measuring Stations (AMS)

NJK Precision’s patented airflow measuring stations are built around a dual-chambered airfoil design β€” the same physics principle as an airplane wing β€” to dynamically normalize turbulent ductwork flows and deliver unmatched measurement accuracy in even the most restricted installations.

πŸ“
Rectangular AMS
For Rectangular Ducts & OA Openings
US Patent 9,909,771 B2 β€” 21 Claims

The core NJK product β€” a perimeter-installed Flow Frame with patented dual-chambered airfoil design. Two frame sizes minimize duct cross-section impact. Available for new construction and retrofit.

  • Small frame: 2.75″ wide (ducts under 18″)
  • Large frame: 5.5″ wide (ducts 18″ or greater)
  • Reads down to 50 FPM airflow velocity
  • Place just 1 duct diameter from 90Β° elbow
  • Β±0.19% uncertainty at 95% confidence (NIST)
  • 1–10 VDC output to BAS; signal in SCFM
21 Patented Claims
β­•
Round AMS
For Circular Ductwork
Adjustable Mounting Bracket

Round station version of the NJK airfoil technology β€” single station covers a range of circular duct diameters through adjustable mounting bracket assemblies, minimizing SKU requirements.

  • Adjustable mounting β€” one station fits multiple diameters
  • Same dual-chambered airfoil sensing principle
  • Thin film resistor Flow Measuring Module
  • NIST-traceable calibration (25–37 flow points)
  • RJ-45 watertight probe/transmitter connections
  • Signal dampening for high-transient & crosswind applications
Calibrated Across Full Flow Range
πŸ”Œ
Multi-Sensor Hub (SPU-M)
Up to 8 Stations, Single Controller
Signal Processing Unit β€” Multiple

An economical multi-station solution not available from competitors β€” one SPU-M monitors up to 8 airflow stations simultaneously, replacing the need for a dedicated display per sensor.

  • Up to 8 stations per SPU-M via Multi Sensor Hub
  • Monitor 4 airflow values simultaneously from one location
  • 24V AC or DC powered
  • Four 1–10 VDC outputs to BAS
  • Total cable run up to 300′ per SPU-M
  • Airflows can be summed for totalization
Hardware & Installation Cost Savings

Damper Louver Solutions (DLS)

NJK Precision’s next generation of precision airflow monitoring β€” designed to mount immediately adjacent to dampers and louvers with lifetime calibration and ultimate placement versatility.

Patent Pending β€” New Design

Install Right Next to a Damper or Louver

The DLS raises the bar on ease of installation, placement flexibility, and performance. Unlike conventional stations that require clearances, the DLS mounts immediately next to a damper or louver without compromising precision accuracy β€” even in non-uniform, non-laminar, or turbulent airflow.

πŸ”© U-Frame ShapeπŸŒ€ Active Airfoil UprightsπŸ”¬ Thin Film Sensing♾️ Lifetime Calibration

DLS Key Features

Installation
  • Mounts immediately next to a damper or louver
  • Interior and exterior applications
  • Single sensor design reduces costs
  • Minimizes airflow restriction
  • Plenum-rated communication cables
Design Components
  • U-Frame with active airfoil uprights (linear ports)
  • Inert airfoil ported to Flow Measuring Module
  • End caps with dual pressure isolation
  • Dual chamber corners and T-couplers
  • Plug & play Flow Measuring Module
Operations
  • Lifetime calibration β€” no re-cal needed
  • Minimal inspection and cleaning only
  • Single-sensor avoids degrading sensor data
  • Advanced thin film thermal dispersion technology
Performance
  • Precision accuracy at any flow rate
  • Works in turbulent and non-laminar air
  • No aggregate data issues
  • Longer sensor life cycle

The NJK Precision Difference

✈️

Aviation-Inspired Airfoil Design

The dual-chambered airfoil Flow Frame works like an airplane wing β€” air momentum over the frame creates differential pressure proportional to mass flow, dynamically normalizing turbulent ductwork airflow.

🎯

NIST-Certified Β±0.19% Accuracy

Each Flow Measuring Module is calibrated across 25–37 flow points on a primary NIST-certified testing stand. Uncertainty is 0.19% at 95% confidence β€” accurate in all temperature and humidity conditions.

πŸ“

Minimal Placement Restrictions

NJK stations can be placed just 1 equivalent duct diameter from a 90Β° elbow β€” vs. 3 required by conventional stations β€” dramatically expanding retrofit and new construction options.

πŸš—

Automotive MAF Sensor Technology

The thin film resistor sensing module uses the same mass airflow (MAF) sensor technology proven in fuel-injected automotive engines for decades β€” delivering reliability and sub-50 FPM low-flow sensing.

πŸ”¬

Low Flow Measurement to 50 FPM

The NJK AMS reads accurately down to 50 feet per minute β€” enabling precise outside air control even when supply fan speeds are reduced, supporting ASHRAE and IAQ compliance at low loads.

πŸ—οΈ

Fast Field Assembly β€” Built to Order

Stations ship unassembled to reduce freight cost and prevent damage. Slip-fit field-adjustable corner pieces connect sections in minutes. Frame is adjustable +0.5″ to +1.25″ to accommodate actual duct dimensions.


Applications & Industries Served
πŸ§ͺ Laboratories & ResearchπŸ₯ Healthcare & Hospitals🏫 Educational Facilities🏒 Commercial Buildings🌿 Healthy Spaces & IAQ🌬️ Outside Air Control🧹 Clean Rooms🦠 Allergen Reduction⚑ Building Automation (BAS)πŸ’¨ Building PressurizationπŸ—οΈ New ConstructionπŸ”§ Retrofit Projects

Specify NJK Precision for Your Project

With 21 patented claims and NIST-certified accuracy to 50 FPM, NJK Precision is the right choice for demanding airflow measurement. Contact CEE for specifications, submittals, and support.

Request a Quote β†’